Heat Pump verse HAVC, 牌子和价位合适吗?

S
SleepMed
楼主 (文学城)

实在太忙,只有一个quote;求建议。

Dallas rental home 5bed/3 bath; 2 story;2600 Sq Ft; built in 2003. No gas,so may have to stick with Heat Pump; otherwise the electricity bill will be too high for Tenant. 

目前是原始的Heatpump;制热有问题,准备换。

new air handler

new filter base

new disconnect,

whip float, switch  etc

10 your parts 2 years labor
Trane 15 seer $ 7000 or Ameristar 14 seer $6500.


二月份,刚刚用过这个subcontrator:
3.5 Ton and 5 ton Trane HAVC 15 seers
gas furnace systems.
coil
condenser
Plenum *4
Disconnect, whip
Float switch
Settlement traps for the gas
New thermostats
Dripping pan
10 year parts 2 year labor
Total $13000

P
Parkbrooke
不是专家. 但是过热过冷的地方heat pump比较吃力,还是传统的HAVC好
徒劳
heat pump在德州应该够用了吧,但是为什么要为tenant省钱呢,不必挑seer高的,性价比低,不值得
S
SleepMed
租客电费太高就要搬家,还是我倒霉啊,

如果是你,你选哪个结果?

S
SleepMed
你说的应该是对的,但是换成havc电费太贵.
b
borisg
dallas is not cold in winter, heatpump should be good.
徒劳
所以挑租客很关键,如果连电费都付不起的话那还是算了吧。
惨白的天使
电费高去怨市场化失灵的电力公司去。怨房东的房客估计电便宜时也能想出法子怨房东
上海大男人
半个专家有看法

没有Gas的地方,猜测就是用电。电是二次能源,用来取暖,效率没有一次能源高,如燃油或天然气。所以用电取暖,电费当然会高,当然这个高是相对用燃油或天然气。如果只有用电,抱怨电费太高是没有道理的,除非像上面的朋友讲是找理由抱怨。

回到heat pump,这是冷暖二用机器。适用酷热但不是酷寒的地方,比如我的老家上海,北京就效果不好。heat pump 设计时的功率需求是按制冷功率计算,制热不够就有一个附加在机器里的电加热器,酷寒时和主机一起供暖,那电费就更厉害了。

如果用新的heat pump 机器,电费会省,主要是新机型效率高,大多机器用了新一代调频马达,极其省电。我在纽约,供暖是用煤气炉,空调用电。自从用新空调机取代旧机器,都是只制冷,电费原来的一半都没有,但机器要大好几千,靠省下的电费,机器的成本肯定短期赚不回来。所以换新机器要再三考虑,原来的能用,就用。小修可以,要大修,换新的。

a
alpha123
怎么知道新机器是调频马达
上海大男人
看技术参数,FM motor
S
SleepMed
没有的选,只租Section8,不然没有现金流
S
SleepMed
过去三年有两次Winter Storm,10 F degree, Heat Pump要人工控制一下
S
SleepMed
最冷的月$200 Verse $ 600 /month;Section8 没有办法,要替他们省钱
s
slow_quick
应该是 invertor motor 吧?