the building supervisor just came to our unit because there is water leaking into the unit downstairs. He came and looked at the air conditioning unit and said you need to send a technician tomorrow to come and fix the pipes and the insulation connecting the unit if not the condensation will keep leaking into the floor below and cause damage.
He said it's not the issue of the filter, which was also very wet, but the insulation and the pipes need to be maintained regularly by a technician.
这个是租客的text
the building supervisor just came to our unit because there is water leaking into the unit downstairs. He came and looked at the air conditioning unit and said you need to send a technician tomorrow to come and fix the pipes and the insulation connecting the unit if not the condensation will keep leaking into the floor below and cause damage.
He said it's not the issue of the filter, which was also very wet, but the insulation and the pipes need to be maintained regularly by a technician.
10年前遇到过类似问题。如果机器在楼上,坚决不用sump pump解决冷凝水。sump pump每出一次问题,楼下就是一次水灾,你就要修一次ceiling。建议改用1” PVC pipe,利用gravity直接引流到下水管道。这要靠谱的多。我改完三个单元后,10年再没出过类似问题。
还是那句话:越是复杂的设计,越不靠谱。反过来,越简单,越可靠。
己可先试。
他的判断是管子的保温层有问题。这几天闷热,如再加上湿热,冷媒管外表面的冷凝水水量非常厉害,就像一罐冰可乐从冰箱里拿出,放在桌上,一会儿,桌面就是一滩水。完好无损的保温层可以防止水汽在管子上冷凝成水滴下。